Use and maintenance of horizontal trough mixer
Mar 19, 2020
I. Instructions and precautions for horizontal trough mixer
1. A dry run test should be performed before use. Before the test run, check the solidity of all the connections of the horizontal trough mixer, the amount of lubricating oil in the reducer and the integrity of electrical equipment, and then close the main switch. Turn on the power and perform a dry run test.
2. The dry run test requires item-by-item tests. Only when abnormal sounds such as abnormal sounds, high heat in the bearing gear, and the temperature rise of the reducer are found, can it be put into production.
3. If it is necessary to shovel the material of the mixer tank wall during operation, bamboo and wooden tools should not be used to avoid injury to the hand.
4. If the machine is found to be vibrating abnormally or making abnormal strange sounds during the use of the horizontal tank mixer, it should be stopped for inspection immediately.
5. The load of the mixer should not be too large. Generally, the load of the motor is used to measure the heavy load current of the 380V motor when mixing. It is normal to not exceed 6 amps. If the load is exceeded, the mixing capacity should be reduced immediately.
6. The shaft seals at both ends of the mixing paddle should be kept clean to avoid blackening and deterioration of the materials. Square holes should be left at the outer barriers at both ends of the mixing tank. The shaft center makes the material in the tank black and deteriorate.
7. Managers must be familiar with the technical performance, internal structure, and control structure of the horizontal tank mixer. During operation, do not leave the work site to prevent malfunctions and damage to the parts. The premise is to ensure safe production.
Maintenance instructions for horizontal trough mixer
1. Regularly inspect the parts, 1-2 times a month. The inspection items include whether the moving parts such as worm gears, worms, bearings, shaft seals are flexible and wearable. Defects should be repaired in time so that the trough mixer can be used normally.
https://www.bolymill.com/